July, 2005 - CPI Shares Details About New TIA-942 Standard Addressing Data Center Design | Chatsworth Products
We use cookies to personalize content and to analyze our traffic. You consent to cookies if you continue to use this website. To find out more or to disable cookies view our Privacy Policy. X

 

CPI Shares Details About New TIA-942 Standard Addressing Data Center Design

WESTLAKE VILLAGE, Calif. – July 7, 2005- Chatsworth Products, Inc. (CPI), a leading manufacturer of structural support systems designed to organize, store and secure computer and communications networks, is pleased to share that the Telecommunication Industry Association (TIA) has endorsed the concept of zone cabling for Data Centers (TIA-942). As the first extensive standard to address data centers, TIA-942 is a valuable tool for the proper design, installation and management of data center cabling.  

In a data center topology, a zone distribution area may be used to locate a zone outlet or consolidation point between the horizontal distribution area and the equipment distribution area to provide more flexibility in moving, adding or changing cabinets of equipment. Only the cables between the zone enclosure and the individual equipment are moved, added or changed eliminating disruption in other zones and re-wiring.

CPI’s consolidation point enclosures include mounting brackets for wiring blocks or patch panels, and are used to reduce the amount of cable affected by a change in the data center. Designing your data center in accordance with the new TIA-942 standard will help ensure robust data center design, standardized organization, ready supply, less re-work and scalability for future applications. Extra connections are planed for each zone and pre-terminated in the consolidation point enclosure. Cables are added between the consolidation point and workspaces as needed.

CPI offers several styles of zone enclosures that can be used under raised floors or in drop ceilings. Enclosures are UL Listed 2043 and can be located in air-handling spaces (the plenum). Raised floor enclosures are placed under a single 2’ x 2’ floor tile making the floor tile the cover. Ceiling enclosures replace a single 2’ x 2’ or 2’ x 4’ drop ceiling tile and the access door provides easy access to equipment.

CPI also offers active telecommunications enclosures for use in the open office environment. These include mounting brackets for patch panels, a ventilation fan, electrical junction box and extra equipment mounting space for active equipment like network switches. Placing a network switch in the enclosure allows users in the zone to connect to the rest of the network through a single cable, typically fiber. The network switch can increase bandwidth in the zone.

For more information about these and other zone and telecommunication enclosures visit, www.chatsworth.com/zonewireless or contact CPI. 

 Raised Floor Enclosure for Fiber   Ceiling Mounted Zone Enclosure 
Raised Floor Enclosure for Fiber
A0822-RF-F     2’ x 2’
 

Ceiling Mounted Zone Enclosure
A1224-LP     2' x 4'
 

                           

About Telecommunications Industry Association 

The Telecommunications Industry Association (TIA) is accredited by the American National Standards Institute (ANSI) to develop and endorse industry standards for a wide variety of telecommunications products. Within TIA, more than 1,500 representatives from manufacturers, service providers and end-users, including the government, serve on the formulating groups involved in standards setting. For a potential project to become a standard it must be circulated and approved by the designated formulating groups. After a potential project has been approved it will then be endorsed by the TIA. 

About Chatsworth Products 
At Chatsworth Products (CPI), it is our mission to address today’s critical IT infrastructure needs with products and services that protect your ever-growing investment in information and communication technology. We act as your business partner and are uniquely prepared to respond to your specific requirements with global availability and rapid product customization that will give you a competitive advantage. At CPI, our passion works for you. With over two decades of engineering innovative IT physical layer solutions for the Fortune 500 and multinational corporations, CPI can respond to your business requirements with unequaled application expertise, customer service and technical support, as well as a global network of industry-leading distributors. Headquartered in the United States, CPI operates from multiple sites worldwide, including offices in Mexico, Canada, China, the United Arab Emirates and the United Kingdom. CPI’s manufacturing facilities are located in the United States, Asia and Europe.

CPI is listed with the General Services Administration (GSA) under Federal Supply Schedule IT 70. Products are also available through GSA Advantage and through Government Wide Acquisition Contracts (GWACs), including GSA Connections and NITAAC-ECS III (www.chatsworth.com/gov).

More Information
www.chatsworth.com
[email protected]
800-834-4969

Media Contact
Raissa Carey
Public Relations 
[email protected]
512-591-9525

©2019 Chatsworth Products, Inc. All rights reserved. Chatsworth Products, Clik-Nut, CPI, Motive, CPI Passive Cooling, Secure Array, eConnect, Evolution, GlobalFrame, MegaFrame, OnTrac, QuadraRack, RMR, Saf-T-Grip, SeismicFrame, SlimFrame, TeraFrame and Velocity are federally registered trademarks of Chatsworth Products. EuroFrame, CUBE-iT and Simply Efficient are trademarks of Chatsworth Products. All other trademarks belong to their respective companies. 
4/18/2024 6:34:42 PM